Skip to Content
FPD.DEV FPD.DEVThe Future of Display & Systems Development
  • Services
  • Products
  • Learning
  • Partners
  • Videos
  • Schedule Free Consultation
  • Sign in
  • 0
  • 0
  • English (US)  Français  Deutsch  Español
FPD.DEV FPD.DEVThe Future of Display & Systems Development
  • 0
  • 0
    • Services
    • Products
    • Learning
    • Partners
    • Videos
  • English (US)  Français  Deutsch  Español
  • Sign in
  • Schedule Free Consultation
  1. Courses
  2. DO-160 Display Qualification: Components, Systems and Installation
  3. Chapter 3 - Moisture and Contamination
Nav
Home └DO-160 Display Qualification: Components, Systems and Installation └Chapter 3 - Moisture and Contamination
DO-160 Display Qualification: Components, Systems and Installation
0 %

Completed

Course content
  • Current course - seven chapters and glossary
    • Chapter 1 - Introduction
    • Chapter 2 - Temperature and Pressure
    • Chapter 3 - Moisture and Contamination
    • Chapter 4 - Mechanical and Special Environments
    • Chapter 5 - Power and Electrical Transients
    • Chapter 6 - EMC, Lightning and ESD
    • Chapter 7 - Integration and Qualification Practice
    • Glossary and complete slide deck
  • 01 — Public foundations and selected preview chapters
    • 00 — Start here: build a defensible display qualification plan
    • 01 — Public chapter: component, system and installed boundaries
    • 02 — Public chapter: read a qualification claim critically
    • 03 — Public chapter: the complete environmental test suite
    • 04 — Public chapter: temperature limits, ramp rates and decompression
  • 02 — Requirements and climatic exposures
    • 05 — Turn display functions into measurable acceptance criteria
    • 06 — Temperature and altitude: construct the procedure
    • 07 — Temperature variation: 5 and 10 °C per minute in practice
    • 08 — Pressure, altitude and rapid decompression
    • 09 — Humidity, water and fluids: qualify the exposed assembly
    • 10 — Salt spray, fungus, sand and dust
  • 03 — Mechanical and special environments
    • 11 — Shock and vibration: the fixture is part of the argument
    • 12 — Explosion proofness, icing and fire applicability
  • 04 — Power, EMC, lightning and ESD
    • 13 — Aircraft power: qualify the complete input path
    • 14 — EMC: emissions and susceptibility are different evidence
    • 15 — Lightning: connect equipment levels to the aircraft installation
    • 16 — Electrostatic discharge and accessible display surfaces
  • 05 — Installation and qualification planning
    • 17 — Installed display verification and human viewing conditions
    • 18 — Build the environmental qualification matrix
  • 06 — Contracts, changes and lifecycle
    • 19 — Specify the testing contract and supplier deliverables
    • 20 — Changes, anomalies, retests and qualification credit
    • 21 — Tests beyond DO-160 and the production boundary
  • 07 — Capstone, references and assessment
    • 22 — Capstone: plan qualification for a complete aircraft display
    • 23 — Reference shelf and practical worksheets
    • 24 — Knowledge check: apply the qualification principles 10 xp

Chapter 3 - Moisture and Contamination

Prev Next
Fullscreen Share Forum

Chapter 3 of 7 | FPD.DEV | Development edition A-P15

Moisture and Contamination

Humidity, water and fluid entry paths; Contamination and material compatibility; Monitoring and evidence for functional acceptance. Use the reading-page controls below the presentation for explanations and worked practice.

This chapter currently has an animated slide presentation and detailed reading. Recorded narration will be added in a future update.

Open chapter with slide navigation and reading-page controls | Download chapter slides PDF (15 pages)

Slide narration transcript

Slide 47: Moisture and Contamination

FPD.DEV. The Future of Display and Systems Development. Welcome to Chapter 3, Moisture and Contamination. We will trace moisture and contamination from the external exposure to the optical materials, electronics and operator interface. Each topic connects the failure mechanism to a test configuration, a monitoring method and an evidence decision.

Slide 48: Humidity, water and fluids

These exposures answer different questions. Humidity can affect optical films, adhesives and insulation through a prescribed temperature and moisture cycle. Waterproofness evaluates selected liquid-water conditions. Fluids susceptibility concerns specified chemicals and contact methods. A sealed front face does not establish rear-connector protection, and water resistance does not establish cleaner compatibility. Map the moisture and chemical paths through the actual assembly. Define the optical, control and physical checks and when they occur, including any required recovery conditions.

Slide 49: Temperature and humidity chambers

These chambers show the equipment used to control temperature and humidity. The controller's display is only one part of the record. Article loading, airflow, temperature sensors and humidity measurement affect the exposure that the display actually receives. Record the prescribed cycle and the required article condition. Include the recovery and functional checks. When comparing a DO-one-sixty humidity result with a military requirement, compare the complete profiles and evaluation rather than the chamber brand or maximum rating.

Slide 50: Polarizer protection in wet environments

I have helped customers whose display polarizers were damaged by humidity or salt fog. One solution used optical bonding to add a protective cover glass. Another laminated PET film to the polarizer and sealed the polarizer edge. These examples give integrators concrete protection options to evaluate. Consider the face and the exposed perimeter together. Specify the materials, adhesive and assembly process, then verify the finished optical stack under the applicable exposure. Check optical performance, adhesion and edge condition. The added glass or film alone does not establish a hermetic enclosure or a qualification result. Keep the humidity, water and salt-exposure requirements separate in the plan.

Slide 51: Humidity reaches the optical stack

Humidity can affect a display through several paths. Water vapour can diffuse through a polymer or enter through an edge seal, while liquid condensation can form when a surface is below the local dew point. Absorbed moisture can change material dimensions and adhesive behaviour. Surface water can increase leakage or change a capacitive touch measurement. These mechanisms need different observations. A hazy bond edge, corroded connector and false touch event should not be grouped under a single description such as moisture failure. Identify the path and the affected function, then choose inspection and monitoring that can distinguish the causes.

Slide 52: A humidity test configuration

Build the humidity specimen as the production configuration requires, including the real sealing and vent details. Follow the selected category, cycle and operating sequence in the adopted standard. Keep chamber records and item operation on a common timeline. For a touch display, capture intended touches and uncommanded events as well as the visible image. At each required check, use the agreed inspection and functional criteria. Photograph condensation, haze and corrosion before handling changes them. Opening the enclosure or wiping the surface can destroy evidence of the failure path. Any extra investigative check must be distinguished from the formal qualification procedure.

Slide 53: Water exposure and entry paths

Waterproofness starts with the installation exposure and the applicable test category. A front face that tolerates a cleaning wipe does not establish protection against every water test. Water can collect at a bezel joint, run along a cable, enter a connector or reach a rear vent. Orient the specimen and arrange its connections as the selected procedure and installation require. Define what function must continue during exposure and what post-test inspection must establish. Where an ingress protection rating is also required, treat its method and acceptance as a separate requirement unless a documented comparison establishes applicable evidence credit.

Slide 54: Fluid compatibility and service cleaning

A coating may tolerate water while a cleaning fluid changes its surface, and an adhesive may swell without an immediate visible bond failure. Identify the specified fluids and the plausible service chemicals, then connect each to the materials it can reach. Follow the qualification method for concentration, application and exposure. Separately evaluate the approved cleaning process where the product requires it. Inspect optical transmission, haze, markings, seal integrity and touch operation as applicable. A coupon can help screen materials, but the assembly adds edges, mechanical stress and material interactions. Keep coupon evidence and complete-display evidence clearly scoped in the qualification matrix.

Slide 55: Worked case: false touches when wet

In this illustrative case, water on the cover causes touch events while the image remains readable. First preserve the touch event log, command output and synchronized video. Determine whether the controller generated a false coordinate, the application acted on it, or only a test tool reported an event. Compare that behaviour with the requirement for operation during the selected exposure. The display has not passed merely because it still shows an image. Possible design responses include controller tuning, cover geometry, drainage and appropriate input validation. Each change can affect dry touch or glove performance, so repeat the affected evaluations on the revised configuration.

Slide 56: Salt spray, fungus, sand and dust

An image can remain visible while corrosion degrades an electrical connection between chassis parts. Acceptance therefore needs the relevant electrical and physical checks as well as visual function. For salt spray category S, the course diagram shows twenty-four hours of fog followed by twenty-four hours of drying, repeated once. That gives forty-eight fog hours across ninety-six elapsed hours, before subsequent evaluation. Category T has a separate sequence. For fungus, sand and dust, consider the actual materials, openings and operating states. Keep material identity and exposure evidence traceable. Here, electrical bonding means a conductive connection for grounding or shielding. Optical bonding refers separately to the adhesive interface in the display optical stack. Salt fog can also damage the polarizer, as discussed earlier in this chapter.

Slide 57: Salt-spray test equipment

This salt-spray chamber illustrates the exposure enclosure and solution controls. The required method governs solution conditions, fallout collection, orientation and exposure sequence. The display's materials, fasteners, connectors and bonds need the applicable inspection and functional checks. A similar chamber may serve different standards, but the procedures and acceptance can differ. Preserve the actual exposure record and the inspection findings. Do not infer a service-life prediction from a salt-exposure photograph or a single pass.

Slide 58: Salt contamination and electrical paths

Salt contamination can create a conductive path when moisture is present and can promote corrosion at contacts, fasteners or shielding joints. Those effects can appear in different ways: leakage, intermittent connection, increased bond resistance or cosmetic change. Define the electrical and physical acceptance criteria before exposure. Preserve the selected salt-fog sequence and recovery conditions because drying and wetting history affect what the specimen experiences. Use post-test inspection to locate deposits and corrosion, then relate them to the functional measurements. Salt-fog qualification is evidence for that procedure. It is not a direct conversion to a number of years in coastal service.

Slide 59: Dust, sand and exposed interfaces

Dust and sand place different demands on a display. Fine dust can accumulate at a connector or block a cooling path, while larger abrasive particles can damage a coating or interfere with a control. The specified particle characteristics, concentration and exposure conditions matter. Assess the actual orientation, enclosure openings and operation called for by the procedure. Afterwards, inspect the exposed surfaces and interfaces before cleaning away evidence. If readability has changed, distinguish scattering from surface damage, a dirty cover or an internal optical defect. A service cleaning instruction also needs to consider whether wiping trapped abrasive particles damages the surface.

Slide 60: Fungus and material susceptibility

Fungus susceptibility depends on the materials and the conditions that support growth. An assembly contains more than its metal enclosure: adhesives, coatings, labels, gaskets and contaminants can matter. Review the adopted section's provisions for material evidence and testing, then document the basis used for the actual configuration. A supplier statement about one resin does not automatically cover an adhesive formulation or an assembled optical stack. Keep material substitutions under change control. If the intended service practice includes cleaning or storage controls, identify those assumptions in the product documentation without using them to silently remove a qualification requirement.

Slide 61: Chapter 3 complete

You have completed Moisture and Contamination. Use the supporting reading pages to work through the examples and record the evidence you would need for your display. Next we continue with Mechanical and Special Environments. FPD.DEV. The Future of Display and Systems Development.

Reading pages

Page 8: Humidity, water and fluids | Page 9: Salt spray, fungus, sand and dust

Page 8: Humidity, water and fluids

Humidity, water and fluids

DO-160 Display Qualification | A-P13 — Development edition

Learning objective: Select exposure faces and acceptance criteria for Sections 6, 10 and 11.

Three different questions

Humidity evaluates moisture exposure over a prescribed cycle. Waterproofness addresses selected liquid-water exposures. Fluids susceptibility assesses specified chemical contacts and their consequences. Passing one does not establish the others. A front-sealed touch display can still have vulnerable rear connectors, a hygroscopic optical bond or a coating attacked by cleaners.

Numerical reference points

DO-160G Section 6 high-humidity phases use 95 ±4% relative humidity. Category A uses a 50 ±2 °C high phase and two 24-hour cycles; B uses 65 ±2 °C and ten cycles; C uses 55 ±2 °C and six cycles. The complete cycles contain changes in conditions: describing them as a constant high-temperature soak misstates the method. Use the applicable cycle figure, conditioning and timing in the standard.

Follow the moisture path

Identify the surfaces actually exposed after installation. Record display angle, drainage, seals, connector backshells and any covers or barriers. If a fixture blocks an opening that is exposed in service, it can invalidate the representation. Where a face-only requirement is intentional, state the excluded surfaces in the claim and installation instructions.

For fluids, identify the chemical, concentration, temperature, contact method, duration, cleaning or drying procedure and subsequent checks required by the selected method. If the operator uses a particular disinfectant, determine whether it is within the contracted fluid set. A vague claim of cleaning-fluid resistance does not address every formulation.

Display-specific checks

Look for haze, delamination, coating damage, discoloration, label loss, touch false activations, leakage and corrosion. Define when optical measurements occur: a wet surface can behave differently from a recovered dry surface. Record both required in-exposure behavior and the prescribed post-exposure evaluation; neither substitutes for the other.

Exercise

A water test used a protective rear cap absent from the proposed aircraft installation. Worked response: either substantiate an equivalent installed protection, revise the installation to include the qualified protection, or test the affected configuration. Do not remove the cap from the report's equipment list and continue using the original claim.

Humidity A/B/C nominal cycle comparison. Slopes are illustrative. The RH return is a control region, not a prescribed falling trace. Source: DO-160G §§6.3.1–6.3.3, printed pp. 6-2–6-4.
Humidity A/B/C nominal cycle comparison. Slopes are illustrative. The RH return is a control region, not a prescribed falling trace. Source: DO-160G §§6.3.1–6.3.3, printed pp. 6-2–6-4.

Humidity conditions: nominal cycle and required tolerances

Original comparison from DO-160G §§6.3.1–6.3.3. Nominal cycle times exclude initial stabilization and final evaluation. Follow all applicable checks and chamber requirements.
ItemABC
Initial stabilization38 ±2 °C; 85 ±4% RH38 ±2 °C; 85 ±4% RH38 ±2 °C; 85 ±4% RH
Rise2 h ±10 min2 h ±10 min2 h ±10 min
High-temperature phase50 ±2 °C65 ±2 °C55 ±2 °C
High-humidity hold95 ±4% RH; ≥6 h95 ±4% RH; ≥6 h95 ±4% RH; ≥6 h
Return phase16 h ±15 min16 h ±15 min16 h ±15 min
Return conditionsGradual decrease to 38 ±2 °C or lower; keep RH high and ≥85%SameSame
Cycles / nominal exposure2 / 48 h10 / 240 h6 / 144 h
Final powered evaluationDrain moisture, do not wipe; apply power within 1 h; warm-up ≤15 min; then required checksSameSame

Polarizer protection: integrator experience

Diggy reports customer cases in which humidity or salt fog damaged the display polarizer. Solutions used included optically bonding a cover glass to the display, or laminating a PET film to the polarizer and sealing its edge. These are application examples, not a universal material prescription or a claim of DO-160 qualification.

Assess the protective face and the exposed perimeter together. Specify the cover or film, adhesive, edge-seal materials and assembly process. Verify the finished optical stack under its applicable exposure, including optical performance, adhesion and edge condition. Do not assume that adding cover glass or PET establishes a hermetic enclosure.

Keep humidity, waterproofness and salt exposure requirements distinct. The protection approach must demonstrate the required performance for each applicable condition.

Page takeaway

  • Map exposure faces and moisture/chemical paths to the actual assembly and required checks.

Supporting page images

Two laboratory environmental chambers with temperature and humidity controls.
Programmable temperature and humidity chambers. The displayed settings illustrate the apparatus; the applicable qualification plan supplies the required limits and sequence.
Photo: Cjp24 · Environmental chambers · CC BY-SA 3.0. Original image, displayed at reduced size.

Engineering application and worked evidence

The following examples develop the display mechanisms and evidence decisions. Numerical values are teaching assumptions, not universal DO-160 limits. Use the adopted procedure for exact test conditions and the product requirements for functional acceptance.

Humidity reaches the optical stack

Humidity can affect a display through several paths. Water vapour can diffuse through a polymer or enter through an edge seal, while liquid condensation can form when a surface is below the local dew point. Absorbed moisture can change material dimensions and adhesive behaviour. Surface water can increase leakage or change a capacitive touch measurement. These mechanisms need different observations. A hazy bond edge, corroded connector and false touch event should not be grouped under a single description such as moisture failure. Identify the path and the affected function, then choose inspection and monitoring that can distinguish the causes.

Basis: RTCA DO-160G, Section 6. Retained reference in 80 Reference Library/Aerospace. Display mechanisms, design responses and worked cases are FPD.DEV engineering teaching synthesis, not additional DO-160 requirements. Numerical examples are illustrative.

A humidity test configuration

Build the humidity specimen as the production configuration requires, including the real sealing and vent details. Follow the selected category, cycle and operating sequence in the adopted standard. Keep chamber records and item operation on a common timeline. For a touch display, capture intended touches and uncommanded events as well as the visible image. At each required check, use the agreed inspection and functional criteria. Photograph condensation, haze and corrosion before handling changes them. Opening the enclosure or wiping the surface can destroy evidence of the failure path. Any extra investigative check must be distinguished from the formal qualification procedure.

Basis: RTCA DO-160G, Sections 3 and 6. Retained reference in 80 Reference Library/Aerospace. Display mechanisms, design responses and worked cases are FPD.DEV engineering teaching synthesis, not additional DO-160 requirements. Numerical examples are illustrative.

Water exposure and entry paths

Waterproofness starts with the installation exposure and the applicable test category. A front face that tolerates a cleaning wipe does not establish protection against every water test. Water can collect at a bezel joint, run along a cable, enter a connector or reach a rear vent. Orient the specimen and arrange its connections as the selected procedure and installation require. Define what function must continue during exposure and what post-test inspection must establish. Where an ingress protection rating is also required, treat its method and acceptance as a separate requirement unless a documented comparison establishes applicable evidence credit.

Basis: RTCA DO-160G, Section 10; IEC 60529 scope comparison. Retained reference in 80 Reference Library/Aerospace. Display mechanisms, design responses and worked cases are FPD.DEV engineering teaching synthesis, not additional DO-160 requirements. Numerical examples are illustrative.

Fluid compatibility and service cleaning

A coating may tolerate water while a cleaning fluid changes its surface, and an adhesive may swell without an immediate visible bond failure. Identify the specified fluids and the plausible service chemicals, then connect each to the materials it can reach. Follow the qualification method for concentration, application and exposure. Separately evaluate the approved cleaning process where the product requires it. Inspect optical transmission, haze, markings, seal integrity and touch operation as applicable. A coupon can help screen materials, but the assembly adds edges, mechanical stress and material interactions. Keep coupon evidence and complete-display evidence clearly scoped in the qualification matrix.

Basis: RTCA DO-160G, Section 11. Retained reference in 80 Reference Library/Aerospace. Display mechanisms, design responses and worked cases are FPD.DEV engineering teaching synthesis, not additional DO-160 requirements. Numerical examples are illustrative.

Worked case: false touches when wet

In this illustrative case, water on the cover causes touch events while the image remains readable. First preserve the touch event log, command output and synchronized video. Determine whether the controller generated a false coordinate, the application acted on it, or only a test tool reported an event. Compare that behaviour with the requirement for operation during the selected exposure. The display has not passed merely because it still shows an image. Possible design responses include controller tuning, cover geometry, drainage and appropriate input validation. Each change can affect dry touch or glove performance, so repeat the affected evaluations on the revised configuration.

ObservationEvidence to retainDecision basis
False coordinateController event logTouch requirement
Unwanted commandApplication outputSystem response
Normal imageOptical recordingImage requirement only

Basis: RTCA DO-160G, Sections 10 and 25; authored case. Retained reference in 80 Reference Library/Aerospace. Display mechanisms, design responses and worked cases are FPD.DEV engineering teaching synthesis, not additional DO-160 requirements. Numerical examples are illustrative.

Practice: Water-induced touch activity

After a specified water exposure, the display still shows its image but has issued two uncommanded touch actions. The operator wiped the cover before the first photograph. Draft the anomaly entry and a follow-up plan.

Model response and review points

Record the actual touch and application outputs, stimulus timing, configuration and known handling. State that wiping removed part of the physical evidence. Compare the actions with the requirement for the operating state during exposure. Investigate the sensing and application path with the real cover and drainage arrangement. Preserve wet-state evidence on the next authorized run, and include dry, glove and edge performance in the change-impact assessment if tuning changes.

Page 9: Salt spray, fungus, sand and dust

Salt spray, fungus, sand and dust

DO-160 Display Qualification | A-P13 — Development edition

Learning objective: Connect material and enclosure evidence to Sections 12–14.

Exposure must reach the relevant parts

Salt spray can affect connector contacts, coating edges, fasteners, grounding joints and conductive optical treatments. A display can still show an image while a bonding joint has deteriorated. Specify the relevant electrical, mechanical and optical checks in addition to appearance. Salt exposure is particularly relevant to maritime or exposed service; the intended installation drives applicability.

DO-160G Section 14 uses a solution of 5 ±1% sodium chloride by mass, at 35 °C, with pH 6.5–7.2 and a collection rate of 1–3 mL per 80 cm² per hour. Category S alternates 24 hours of fog and 24 hours of drying, then repeats: 48 hours of fog in a 96-hour sequence before subsequent checks, subject to the adopted procedure. Category T uses a different sequence including two 48-hour fog periods and drying stages. Do not copy a Category S total duration into a Category T purchase specification.

Fungus resistance

Assess susceptible materials including adhesives, coatings and other organic materials. Where the selected category permits material-based substantiation, retain the identification and rationale for the actual materials used. A supplier's generic material family statement may not identify additives, finish or adhesive changes. Otherwise follow the applicable exposure and evaluation procedure.

Sand and dust

Consider optical abrasion, ingress, clogged cooling paths, moving controls and electrical connections. Define openings, seals, operational states and orientation as required by the selected category. A fan operating during service but disabled during a test can change both ingestion and cooling; the procedure and representation must justify the state used.

Exercise: corrosion with continued operation

After exposure the image works, but a chassis bonding joint is visibly corroded and has changed resistance. Can the unit pass solely because the image is present? Worked response: assess the agreed bonding, corrosion, physical and functional criteria. Image presence is insufficient evidence of electrical protection or long-term integrity. If a requirement was omitted from the plan, record the gap and obtain a technically justified disposition rather than inventing a favorable limit afterward.

Evidence to retain

Photographs before and after exposure, material and finish identity, contact and bonding measurements where required, chamber conditions, collection checks, cleaning/drying history and functional results make the report reviewable. Keep any disassembly effects distinct from exposure damage.

Category S salt-fog and drying sequence. Default Category S only; not a Category T timeline. Source: DO-160G §14.3.6.6.
Category S salt-fog and drying sequence. Default Category S only; not a Category T timeline. Source: DO-160G §14.3.6.6.

Salt-spray conditions and Category S timing

Original selection from DO-160G §§14.3.4–14.3.6.6. Category T has a separate procedure; no S-to-T equivalence is implied.
ParameterSelected requirement / meaning
Solution5 ±1% NaCl by mass; required salt purity and solution checks also apply
Exposure-zone temperature35 °C
Collected-solution pH6.5–7.2 at the specified measurement conditions
Collected fallout1–3 mL per 80 cm² per hour; average over at least 16 h
DryingStandard ambient temperature; RH ≤50%; 24 h per drying stage
Default S sequence24 h fog → 24 h dry → repeat once
After final dryingOperate and check required performance; inspect and evaluate corrosion

Electrical bonding and polarizer damage

Here, chassis electrical bonding means the conductive connections between enclosure parts, grounding or shielding features. Corrosion can degrade those connections while an image remains visible. State electrical bonding explicitly to distinguish this mechanism from optical adhesive bonding.

Salt fog can also damage an exposed polarizer, as reported in Diggy's customer examples on Page 08 in Chapter 3. Include the optical face and polarizer perimeter in the protection and inspection plan, alongside relevant electrical connections. Optical cover-glass bonding and PET lamination with a sealed polarizer edge are candidate approaches that require verification on the actual assembly.

Page takeaway

  • Identify vulnerable materials, bonds and openings and define physical as well as functional acceptance.

Supporting page images

Salt-spray chamber with transparent lid, solution reservoir and fluid controls.
A salt-spray chamber used for accelerated materials exposure. For a display assembly, inspect the enclosure, fasteners, connector interfaces and optical stack as applicable; the agreed DO-160 procedure determines the exposure and acceptance criteria.
Image: Cjp24 · Salt spray chamber · CC BY-SA 3.0. Source image retained unchanged; displayed at reduced size.

Engineering application and worked evidence

The following examples develop the display mechanisms and evidence decisions. Numerical values are teaching assumptions, not universal DO-160 limits. Use the adopted procedure for exact test conditions and the product requirements for functional acceptance.

Salt contamination and electrical paths

Salt contamination can create a conductive path when moisture is present and can promote corrosion at contacts, fasteners or shielding joints. Those effects can appear in different ways: leakage, intermittent connection, increased bond resistance or cosmetic change. Define the electrical and physical acceptance criteria before exposure. Preserve the selected salt-fog sequence and recovery conditions because drying and wetting history affect what the specimen experiences. Use post-test inspection to locate deposits and corrosion, then relate them to the functional measurements. Salt-fog qualification is evidence for that procedure. It is not a direct conversion to a number of years in coastal service.

Basis: RTCA DO-160G, Section 14. Retained reference in 80 Reference Library/Aerospace. Display mechanisms, design responses and worked cases are FPD.DEV engineering teaching synthesis, not additional DO-160 requirements. Numerical examples are illustrative.

Dust, sand and exposed interfaces

Dust and sand place different demands on a display. Fine dust can accumulate at a connector or block a cooling path, while larger abrasive particles can damage a coating or interfere with a control. The specified particle characteristics, concentration and exposure conditions matter. Assess the actual orientation, enclosure openings and operation called for by the procedure. Afterwards, inspect the exposed surfaces and interfaces before cleaning away evidence. If readability has changed, distinguish scattering from surface damage, a dirty cover or an internal optical defect. A service cleaning instruction also needs to consider whether wiping trapped abrasive particles damages the surface.

Basis: RTCA DO-160G, Section 12. Retained reference in 80 Reference Library/Aerospace. Display mechanisms, design responses and worked cases are FPD.DEV engineering teaching synthesis, not additional DO-160 requirements. Numerical examples are illustrative.

Fungus and material susceptibility

Fungus susceptibility depends on the materials and the conditions that support growth. An assembly contains more than its metal enclosure: adhesives, coatings, labels, gaskets and contaminants can matter. Review the adopted section's provisions for material evidence and testing, then document the basis used for the actual configuration. A supplier statement about one resin does not automatically cover an adhesive formulation or an assembled optical stack. Keep material substitutions under change control. If the intended service practice includes cleaning or storage controls, identify those assumptions in the product documentation without using them to silently remove a qualification requirement.

Basis: RTCA DO-160G, Section 13. Retained reference in 80 Reference Library/Aerospace. Display mechanisms, design responses and worked cases are FPD.DEV engineering teaching synthesis, not additional DO-160 requirements. Numerical examples are illustrative.

Practice: A material substitution after contamination tests

The supplier changes the bezel coating and adhesive after salt-fog and fungus evidence was collected. What can the old reports support?

Model response and review points

They remain evidence for their identified tested configurations. Compare the material formulations, substrate preparation, cure and exposed geometry. Assess corrosion, moisture paths, adhesion and fungus susceptibility using the applicable method provisions. Document the basis for retaining each result and the additional analysis or test needed. A commercial description such as equivalent coating is insufficient by itself to close the review.

References and sources
  • Master Bond, Bonding Substrates with Different Thermal Expansion Coefficients: Thermal mismatch
  • 3M, Structural Adhesives FAQs: Temperature-dependent properties and failure location
  • NASA, Space Shuttle Return To Flight Gets A LIFT From NASA Dryden F-15B; mechanism example, not display qualification evidence: Trapped gas expansion and adhesive damage
  • DAEIL Systems, Active vs. Passive Vibration Isolation; general mechanics, not an aircraft mount selection: Passive isolation and resonance
  • CDTech, Mura and Luminance Uniformity: Causes, Detection and Acceptance: LCD mounting stress and cell gap
  • Focus LCDs: Temperature Consideration for Displays
  • Tianma: SLT-Super Low Temperature Technology
  • www.rtca.org: RTCA DO-160 publications and supporting material

This course is a living document. Enrolled learners typically receive updates when chapters are revised. Use your project’s adopted standards and qualification baseline.

  • About
  • Comments (0)
Rating
0 0

There are no comments for now.

Join this Course
to be the first to leave a comment.

Prev Next

Display engineering with an LCD focus We work primarily with LCD displays, including IPS, FFS, VA and other LCD technologies, with optical enhancements, touch integration, backlights and supporting electronics. We also evaluate other display technologies when they suit the application.

Explore LCD optics with OpticalOracle™

Subscribe to the FPD.DEV newsletter

Get display and embedded engineering articles, Edge AI insights, tool updates and product news by email.

Thanks for registering!

Subscribe

By subscribing, you agree to receive the FPD.DEV newsletter. You can unsubscribe at any time. See our Privacy Policy.


FPD.DEV
The Future of Display & Systems Development

  • Contact Us




  • Privacy Policy

 

 

Get in touch

Operated by Colabmo · Quality, operations & ERP support.


Cookie Policy

Copyright © 2026 Colabmo ​ ​
Powered by Colabmo
Powered by Colabmo

Essential cookies support website functions. With your permission, Google Analytics measures visits and Microsoft Clarity records masked interactions, heatmaps and session replays on approved public pages. Optional embedded features may also contact their providers. These providers receive usage and device data; Microsoft may use data for its own purposes, including advertising. You can reject optional services and change your choice later. Cookie PolicyPrivacy Policy

Allow all optional cookies Only essential cookiesManage choices